Product: ZRC Cold Galvanizing Paint (1 liter can ~ 2.7kg)
– 1 component paint.
– After painting, the plating layer contains 95% zinc after drying, providing cathodic corrosion protection (UL standard).
– Standard for each kg of paint to cover 4m2 with a thickness of 40µm.
– Meets many international standards such as ASTM-B117-73 (3,000-hour test in salt mist environment), DOD-P-21035A (standard for repairing damaged hot-dip galvanized coating), MIL-P-26915A (zinc material standard) …
– Continuous temperature tolerance is 177oC, maximum is 399oC.
– Solvent used: xylene or petroleum jelly. Solvent mixing ratio 10-20% volume (according to manufacturer's recommendation).
– Made in USA (ZRC Worldwide).
SPECIFICATIONS |
ZRC WORLDWIDE |
Product code |
GAL-1/4 |
Specification |
1 liter or 2.7kg can |
Color |
Light gray |
Origin |
USA |
Characteristic |
Organic base with 99.5% pure zinc compound |
Zinc content in the coating after drying
(ASTM A780 standard)
|
95% |
Specific gravity (kg/liter) |
2.7 |
Solids content in solution (%V) |
52% |
Paint rate 1 coat |
4 m2 |
Paint thickness 1 layer |
35 – 40 μm |
Conductivity of the coating |
75 milli ohms |
Temperature tolerance |
399oC |
Paint film drying time – touch |
5-10 minutes |
Paint film hardening time |
24 hours |
Corrosion resistance life (2 coats) |
15 – 20 years |
Application: |
+) Replace and repair hot-dip galvanized layer:
– Repairing hot-dip galvanized coating damaged by welding, cutting, drilling holes.
– Paint to restore hot-dip galvanized surfaces that have been corroded by the environment.
– Galvanizing at the construction site or production site without having to bring it to a hot-dip galvanizing workshop.
– As an anti-rust primer for metal surfaces combined with traditional topcoat paint to achieve the desired color.
+) Application fields:
– Electric poles, lighting poles, parabolic antennas, radar stations.
– Construction structure: wharf, factory, fence, offshore equipment, tanks, pipelines.
– Maintenance of equipment and accessories in power distribution and transmission systems and power transformer stations.
– BTS telecommunication station.
– Electricity, oil and gas, transportation, aquaculture, industrial plants and public works. |
INSTRUCTIONS FOR USE:
a/ Surface Treatment
– Grease, dirt and humid air can affect the adhesion of the spray film, so clean grease and dirt with alcohol or industrial gasoline to completely dry the surface.
– Clean all rust on the surface with sandblasting gun, grinder or specialized acidic cleaning solutions.
b/ How to Use
– Stir the solution for at least 10 – 15 minutes to mix the mixture well.
– Can add solvent (xylene, aromatic gasoline or cream gasoline) at a ratio of 5-10% by volume (if using brush or roller), 10-15% by volume (if using spray gun)
– Brush, roll or spray 1 layer onto the product to be galvanized, after 15 minutes the surface will dry quickly (can be touched), and after 12-24 hours the paint film will be completely dry.
– Can apply second coat after 12-24 hours.
– Clean painting tools (brush, roller or spray gun) for next use.